The AL100UL power supply converts 16.5VAC, 20VA to a 12VDC power limited output (see specifications).
The AL100UL is UL Listed for burglar alarm applications.
Specifications:
Installation Instructions:
Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all local
codes and authorities having jurisdiction. Product is intended for indoor use only.
1. Mount the unit in desired location. Mark and predrill holes in the wall to line up with the top two keyholes in the
enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure’s
upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the
enclosure. Drill the lower holes and install the two fasteners. Place the enclosure’s upper keyholes over the two upper
screws. Install the two lower screws and make sure to tighten all screws (Enclosure Dimensions, pg. 8). Secure
enclosure to earth g
round (Fig 1, pg. 3).
2.
Connect a 16.5VAC, 20VA Class 2, UL Listed plug-in transformer to the terminals marked AC.
3. Measure output v
oltage before connecting devices. This helps avoid potential damage.
4. Connect devices to be powered to terminals marked [+ DC - ].
5. Connect the stand-by battery to terminals marked [- BAT +] (battery leads included).
6. Connect appropriate signaling notification devices to AC Fail and Low Bat supervisory relay outputs.
Note: To meet UL requirements, AC Supervisory outputs must be connected to the zone of Alarm Control Panel
or to visual
A
C trouble indicator.
Note: For Access Control applications, batteries are optional. When batteries are not used a loss of
A
C will result in
the loss of output voltage. When the use of stand-by batteries are desired, they must be lead acid or gel type.
Maintenance:
Unit should be tested at least once a year for the proper operation as follows:
Output Voltage Test: Under normal load conditions, the DC output voltage should be checked for proper voltage level
(see power supply voltage output specifications chart).
Battery Test: Under normal load conditions check that the battery is fully charged, check specified voltage both at bat-
tery terminal and at the board terminals marked [- BAT +] to insure there is no break in the battery connection wires.
Note: Maximum charging current under dischar
ge is 500mA.
Note: Expected battery life is 5 y
ears, howev
er it is recommended changing batteries in 4 years or less if needed.
AL100UL - UL Listed
Linear Power Supply/Charger
Rev. 062001
Agency Listings:
UL Listed Standard for Power Supplies
for Use with Burglar Alarm System
Units (UL 603).
CUL Listed - CSA Standard
C603-M1988, Burglar Alarm System.
Class 2 Rated power limited output.
Input:
16.5VAC, 20VA from UL Listed, Class 2 transformer.
Output:
12VDC power limited output.
Maximum charge current is .5 amp.
.75 continuous supply current at 12.5 to 13.9VDC.
Filtered and electronically regulated output.
Battery Backup:
Built-in charger for sealed lead acid or gel type batteries.
Automatic switch over to stand-by battery when AC fails.
Battery Backup (cont’d):
Low battery disconnect prevents batteries from
deep discharge.
Supervision:
Low battery and AC fail supervision form “C” contacts
(1 amp @ 28VDC).
Visual Indicators:
AC input and DC output LED indicators.
Additional Features:
Short circuit and thermal overload protection.
Unit is complete with power supply and enclosure.
Includes battery leads.
Enclosure Dimensions:
8”H x 7.25”W x 3.5”D
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Linear Power Supply/Charger

Overview:The AL100UL power supply converts 16.5VAC, 20VA to a 12VDC power limited output (see specifications). The AL100UL is UL Listed for burglar al

Page 2 - LED Diagnostics:

- 2- AL100ULLED Diagnostics:Red (DC) Green (AC) Power Supply Status ON ON Normal operating condition.ON OFF Loss of AC, Stand-by battery supplying pow

Page 3 - Terminal Identification:

AL100UL - 3-Terminal Identification:Terminal Function/DescriptionLegendAC/AC Low voltage AC input (16.5VAC/20VA). UL Listed. Class 2 plug-in transform

Page 4 - Enclosure Dimensions:

- 4- AL100UL140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056web site: www.altronix.com, e-mail: [email protected], Lifet

Comments to this Manuals

No comments