Rack Mount Series
Installation Guide
Models Include:
Maximal1RHD Maximal1RD
- 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 amp.
- Eight (8) PTC Protected Outputs. - Sixteen (16) PTC Protected Outputs.
Maximal3RHD Maximal3RD
- 12VDC or 24VDC @ 6 amp. - 12VDC or 24VDC @ 6 amp.
- Eight (8) PTC Protected Outputs. - Sixteen (16) PTC Protected Outputs.
Maximal33RD
- 12VDC and/or 24VDC @ 12 amp.
- Sixteen (16) PTC Protected Outputs.
More than just power.
TM
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - Installation Guide

Rev. 010708Rack Mount SeriesInstallation GuideModels Include:Maximal1RHD Maximal1RD- 12VDC @ 4 amp or 24VDC @ 3 amp. - 12VDC @ 4 amp or 24VDC @ 3 a

Page 2 - Table of Contents:

- 10 - Maximal Rack Access Power Controllers (PTC)Fig. 12Fig. 13Fig. 14Mounting Options:Rack Mount Installation1. Remove center brace from rack m

Page 3

Maximal Rack Access Power Controllers (PTC) - 11 - 3.125" 8.5" .75" 19.125" 17.625" --- + OUT1 --- + OUT2 --- + OUT3

Page 4 - Installation Instructions:

- 12 - Maximal Rack Access Power Controllers (PTC)Altronix Corp.14058thStreet,Brooklyn,NewYork11220USA,718-567-8181,fax:718-567-9056web

Page 5

- 2 - Maximal Rack Access Power Controllers (PTC)Table of Contents:MaximalD Rack Mount Series Overview ...

Page 6 - Switch Detail

Maximal Rack Access Power Controllers (PTC) - 3 - Overview:These units distribute and switch power to access control systems and accessories. They

Page 7 - FIRE ALARM

- 4 - Maximal Rack Access Power Controllers (PTC)Installation Instructions:Important: Adjust output voltages, and Fire Alarm Interface configurati

Page 8 - Power Supply Board

Maximal Rack Access Power Controllers (PTC) - 5 -  b. Foralatchingfirealarminterfaceconnectanormally[NO]resetswitchtotheremovablet

Page 9 - FACP Hook-Up Diagrams

- 6 - Maximal Rack Access Power Controllers (PTC)WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture

Page 10 - Wall Mount Installation

Maximal Rack Access Power Controllers (PTC) - 7 - --- +DC INPUT+ -- OUT1+ -- OUT2+ -- OUT3+ -- OUT4SW1SW2FIRE ALARMRESETClip Switch fo

Page 11 - Line Cord

--- BAT + Built-inBattery ChargingPower Supply BoardLG NOFF ONLOW BATNC C NO NC C NOAC FAIL--- BAT +--- DC +AC DC5A 250V ---

Page 12 - Altronix Corp

Maximal Rack Access Power Controllers (PTC) - 9 - FACP Hook-Up DiagramsPolarity Reversal Input from FACP Signal Circuit Output(Polarity is referenc