Page 1 - AL642ULADA

Rev. 042209AL642ULADANAC Power ExtenderInstallation Guide(see 42 Application Guide for additional information)Altronix Corp.140 58th St. Brooklyn, NY

Page 2 - - 2 - AL642ULADA

- 10 - AL642ULADAAppendix A - UL Listed Compatible DevicesA.1 Four (4) Wire Smoke DetectorsTableA-1belowlistsfour(4)wiresmokedetectorscomp

Page 3 - Stand-by Specifications:

AL642ULADA - 11 -A.1 Four (4) Wire Smoke Detectors (cont.)Smoke Detector/BaseDetector TypeMax StandbyCurrent (mA)AlarmCurrent (mA)SystemSensor4W

Page 4 - IN>OUT SYNC

- 12 - AL642ULADAA.4 StrobesTableA-4belowlistsstrobescompatiblewithAL642ULADANACoutput.Wheelock Devices:Sychronizing HornsAH-12 AH-12WP

Page 5 - AL842LGK - Logic Board

AL642ULADA - 13 -A.4 Strobes (cont.)Wheelock Devices:Coded Audible AppliancesAMT-12/24AMT-12/24-NYCCH70CSX10-24-DCMT-12/24AMT4-12/24AMT4-1

Page 6 - - 6 - AL642ULADA

- 14 - AL642ULADAA.4 Strobes (cont.)Amseco Devices:ModelsH24RH24WHP-25TMH12/24MH-120RSD24-153075RSD24W75110SAD-24-153075SAD2475110SCM24C-177SCM24W

Page 7 - +

AL642ULADA - 15 -Notes:

Page 8 - Maintenance:

Altronixisnotresponsibleforanytypographicalerrors.14058thStreet,Brooklyn,NewYork11220USA,718-567-8181,fax:718-567-9056website:www.a

Page 9 - Battery Calculation Worksheet

- 2 - AL642ULADAAgency Listings:• ULListedControlUnitsandAccessoriesfor FireSystems(UL864).• MEA-NYCDepartmentofBuildingsApprov

Page 10 - - 10 - AL642ULADA

AL642ULADA - 3 -Power Supply Specifications:AC Input:120VAC60Hz,4amp.Output:Four(4)regulatedsupervisedNACoutputcircuits,24VDC,2.5ampm

Page 11 - AL642ULADA - 11

- 4 - AL642ULADA6. ConnectFACPoutputtothedesiredAL842LGKlogicboardinputs,andnotificationappliancestothedesiredAL842LGK logicbo

Page 12 - - 12 - AL642ULADA

AL642ULADA - 5 -Note:TheAL642ULADAwillonlysynchronizehorns,horn/strobesandstrobesthatcontainsynchronizationcapability.Contactsignalm

Page 13 - AL642ULADA - 13

- 6 - AL642ULADANote: Unit is equipped with two (2) 1 amp max. auxiliary outputs: “AUX1” will automatically disconnect whenAC is lost. “AUX2” wi

Page 14 - Faraday Devices:

AL642ULADA - 7 -Fig. 2* Indicatesexistingtroublecondition.Whenatroublecondition(open,shortorground)occursonaspecificoutput,the

Page 15 - AL642ULADA - 15

- 8 - AL642ULADAOptional hookups:1- BatteryandACmonitoring:ACorBatteryFailconditionwillcausethecommontroubleinput[C“FAULT”NC]to

Page 16 - (H x W x D approximate):

AL642ULADA - 9 -Battery Calculation WorksheetUnitsarecapableofrecharging40AHbatterymax.Iftotalampere-hourrequiredexceeds40AH,decreas