ALTV248UL3 Series
CCTV Power Supplies
Installation Guide
Models Include:
ALTV248UL3 ALTV248ULCB3
- 24VAC @ 3.5 amp (85VA) - 24VAC @ 3.5 amp (85VA)
or 28VAC @ 3 amp (85VA). or 28VAC @ 3 amp (85VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
- Factory installed 3-wire linecord. - Factory installed 3-wire linecord.
ALTV248175UL3 • ALTV248175ULCB3
- 24VAC @ 7 amp (175VA) - 24VAC @ 7 amp (175VA)
or 28VAC @ 6.25 amp (175VA). or 28VAC @ 6.25 amp (175VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
- Factory installed 3-wire linecord. - Factory installed 3-wire linecord.
ALTV248300UL3 • ALTV248300ULCB3
- 24VAC @ 12.5 amp (300VA) - 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA). or 28VAC @ 10 amp (280VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
- Factory installed 3-wire linecord. - Factory installed 3-wire linecord.
ALTV248300ULM3 • ALTV248300ULCBM3
- 24VAC @ 12.5 amp (300VA) - 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA). or 28VAC @ 10 amp (280VA).
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
- Factory installed 3-wire linecord. - Factory installed 3-wire linecord.
ALTV248600UL3 ALTV248600ULCB3
- 24VAC @ 25 amp (600VA) - 24VAC @ 25 amp (600VA)
or 28VAC @ 20 amp (560VA). or 28VAC @ 20 amp (560VA)
- Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.
- Factory installed 3-wire linecord. - Factory installed 3-wire linecord.
Rev. 040506
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - ALTV248UL3 Series

ALTV248UL3 Series CCTV Power SuppliesInstallation GuideModels Include:• ALTV248UL3 • ALTV248ULCB3 - 24VAC @ 3.5 amp (85VA) - 24VAC @ 3.5 amp

Page 2 - Overview:

INPUTN P SINPUTN P SWhiteLeadXFMR*BlackLead115VAC input,50/60 Hz.XFMR*GreenLead(Ground)Connected to Doornon-power limited non-power limited non-powe

Page 3 - Enclosure Dimensions:

1.00" 1.75" 1.00" 1.25" 1.25" 8.13" 1.00" 1.00" 1.25" 8.13" 7.25" 7.25" 1.00" 3.85&qu

Page 4 - - 4 - ALTV248UL3series

Altronix Corp.140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056web site: www.altronix.com, e-mail: [email protected], Lif

Page 5 - ALTV248UL3series - 5

Number of OutputsIndividual Output Current (max per output not to exceed total output current)- 2 - ALTV248UL3seriesAltronix Model NumberTotal O

Page 6 - MAIN FUSE

Specification: Installation Instructions:Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/NFPA 72/ANSI, and with all lo

Page 7 - ALTV248UL3series - 7

WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified servi

Page 8 - Illuminated Power Disconnect

Fig. 1 ALTV248UL3XFMRWhiteLead BlackLead BlackLead non-power limited non-power limited 115VAC Input 50/60 Hz. ON OFFMAIN FUSECOMMON POWER OUTPU

Page 9 - ALTV248600UL3

Green Lead(ground)MAIN FUSEBlack Lead White Lead 115VAC input 50/60 Hz XFMRCOMMON POWER OUTPUTSFUSED POWER OUTPUTSNPSnon-power limited Clas

Page 10 - Fig. 10a

White Lead NCOMMON POWER OUTPUTSPFUSED POWER OUTPUTSD1INPUTNPSR1LEDnon-power limitedXFMR*115VAC input50/60 HzGreen Lead(ground)MAIN FUSEIllu

Page 11 - • ALTV248UL3 • ALTV248ULCB3

Transformer underneathpower supply boardWhite LeadBlack LeadXFMR*NCO MMON P OWE R OUTP UTSPFU SED P OWE R OUT PUTS1 2 3 4 5 6 7

Page 12 - 12”H x 7.25”W x 4.5”D

WhiteLeadXFMR*BlackLead115VAC input,50/60 Hz.XFMR*INPUTN P SINPUTN P SGreenLead(Ground)Connected to Doornon-power limited non-power limited non-powe