Altronix NetWay16M Installation Guide Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
- 2 - NetWay8M/ NetWay16M
Overview:
Altronix NetWay8M/NetWay16M Managed Midspans provide power and pass data for PoE compliant cameras/edge devic-
es. Cameras/edge devices may be located up to 100m (328 ft.) from the NetWay unit. A NetWayXT repeater module can be
utilized to extend the distance an additional 100m (328 ft.) for a total range of up to 200m (656 ft.). A maximum range of
600m (1968 ft.) is possible using multiple repeaters, based on camera/device port requirement. NetWay Managed Midspans
are capable of supporting non-PoE compliant fixed and PTZ IP cameras utilizing NetWay1512 or NetWay3012 adapters.
NetWayM Specifications:
NetWay8M:
•Eight(8)portsofcameras/edgedevicesoverethernet(CAT5)
cable up to a distance of 100m (328 ft.) per port.
•115VAC60Hz,3amp(NetWay8M).
NetWay16M:
•Sixteen(16)portsofcameras/edgedevicesoverethernet(CAT5)
cable up to a distance of 100m (328 ft.) per port.
•115VAC60Hz,4.9amp(NetWay16M).
Common Specifications:
Agency Listings:
•UL/CULListedforInformationTechnologyEquipment
(UL60950-1).
• ULListedforAccessControlSystems(UL294).
• CEapproved.
Power:
•UnitsuppliesPoEoutputvoltage(55V),andupto30Wmax.
full power per port. Total power: NetWay8M - 150W,
NetWay16M - 300W.
•IEEE802.3afandIEEE802.3atcompliant(PoEPlus).
•Alloutputcircuitsarepowerlimited.
•Shortcircuitprotection.
Functions:
•ProgrammblePoEshutdownforeachport.Utilizedto
reset cameras/edge devices
(see Technical Specifications pg. 5).
• PoEmanualshutdown(ForUL60950-1applications
only) (see Technical Specifications pg. 5).
•Autodetectionandprotectionoflegacy
non-PoE cameras/edge devices.
Features:
•LANorlaptopconnectionenablesprogrammingof
PoE shutdown and port monitoring.
•Userinterface(Fig. 5, pg. 7).
•Illuminatedmasterpowerdisconnectcircuitbreaker
with manual reset (switch).
•IndividualportstatusLEDs.
•IEC320-3-wiregroundedlinecord(detachable).
•Unitcanberackorshelfmounted.
•1UrackmountchassisforuseinstandardEIA19”rack.
Accessories:
NetWay1512:
•15Wadapterfornon-PoEcompliantIPcameras.
(ForUL60950-1applicationsonly).
NetWay3012:
•25Wadapterfornon-PoEcompliantIP
fixed or PTZ cameras.
(ForUL60950-1applicationsonly).
NetWayXT:
•PoErepeatermoduleextendsrange100m(328ft.)
(ForUL60950-1applicationsonly).
Installation Instructions:
WiringmethodsshallbeinaccordancewiththeNationalElectricalCode(ANSI/NFPA70),localcodes,andtheauthoritieshaving
jurisdiction.
NetWayM is not intended to be connected to outside plant leads. These products are for indoor use only and must be
installed within the protected premises.
1. AttachmountingbracketstoNetWayMunitforrackorwallmountinstallation(Figs. 8 or 9, pg. 10).
Affix rubber pads to NetWayM for shelf installation (Fig. 10, pg. 10).
2. Securetheunitinarackorplaceunitonashelfasdesired.
Note:Thefollowingfactorsshouldbetakenintoconsiderationwheninstallingtheserackmountunits:
a.Theunitistobeinstalledinaspacewherethemaximumambienttemperaturedoesnotexceed104ºF(40ºC).
b.Takecaretoinsurethereissufficientairflowaroundtheunitandthatobstructionsdonotimpedeit.
c.Whenmountingunitsinrack,takecaretoavoidunevenloadingwhichcancauseahazardouscondition.
3. Setilluminatedmasterpowerdisconnectcircuitbreakertothe(OFF)position(Fig. 1g, pg. 3).
4. PlugthegroundedAClinecord(included)intotheIEC320connectoroftheNetWayMunit
(Fig. 1h, pg. 3).Plugunitintoareliableearthgroundedsocket.Whenusingmultipleunitsthesumoftheindividual
nameplateratingsshouldnotexceedthesupplycircuitrating.DonotConnectToAReceptacleControlledByA
Switch.
5. Connectstructuredcablesfromportmarked[IN]onNetWayMtothecorrespondinginputsofanethernetswitchor
video server (Fig. 1b, pg. 3, Fig. 4, pg. 5).
Note:AllcablingandwiremustbeULListedand/orRecognizedwiresuitablefortheirapplication.
6. Connectstructuredcablesfromportmarked[OUT]onNetWayMtoPoEcompliantcamera/edge
devices (Fig. 1a, pg. 3, Fig. 4, pg. 5).
Note: ForUL294applications,theproductsaretobetestedaspartofacompleteAccessControlSystemandin
accordancewithULListedAccessControlDevices.
Page view 1
1 2 3 4 5 6 7 ... 11 12

Comments to this Manuals

No comments