Altronix ALTV2432600ULCB3 Installation Instructions User Manual

Browse online or download User Manual for Accessories for electrical Altronix ALTV2432600ULCB3 Installation Instructions. Altronix ALTV2432600ULCB3 Installation Instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
ALTV2432UL Series
CCTV Power Supplies
Installation Guide
Models Include:
ALTV2432UL ALTV2432ULCB
- 24VAC @ 7 amp (175VA) - 24VAC @ 7 amp (175VA)
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
ALTV2432300UL ALTV2432300ULCB
- 24VAC @ 12.5 amp (300VA) - 24VAC @ 12.5 amp (300VA)
or 28VAC @ 10 amp (280VA). or 28VAC @ 10 amp (280VA).
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
ALTV2432600UL ALTV2432600ULCB
- 24VAC @ 25 amp (600VA) - 24VAC @ 25 amp (600VA)
or 28VAC @ 20 amp (560VA). or 28VAC @ 20 amp (560VA).
- Thirty-two (32) Fuse Protected Outputs. - Thirty-two (32) PTC Protected Outputs.
Rev. 020604
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - ALTV2432UL Series

ALTV2432UL Series CCTV Power SuppliesInstallation GuideModels Include:• ALTV2432UL • ALTV2432ULCB - 24VAC @ 7 amp (175VA) - 24VAC @ 7 amp (175VA)- Thi

Page 2 - Enclosure Dimensions:

Overview:These Altronix CCTV Power Supplies provide 24VAC/28VAC, (ALTV2432UL and ALTV2432ULCB provide 24VAC),distributed via thirty-two (32) fuse or P

Page 3 - Terminal Identification:

- 3 -7. Turn main switch on unit to the ON (RESET) position (Figs. 1-3, pgs. 4-6).8.Green LED(s) will illuminate when unit is powered.9.Upon completio

Page 4 - ALTV2432UL • ALTV2432ULCB

- 4 -Fig. 1ALTV2432UL • ALTV2432ULCBWhiteLeadBlackLead115VAC input50/60 Hz.Used on PTC Models(example: ALTV2432ULCB)GroundConnected to Doornon-power l

Page 5 - (example: ALTV2432300ULCB)

- 5 -Fig. 2ALTV2432300UL • ALTV2432300ULCBBlack Lead White Lead 115VAC input50/60 HzUsed on PTC Models(example: ALTV2432300ULCB)XFMR*GroundConnected t

Page 6 - (example: ALTV2432600ULCB)

- 6 -WhiteLeadXFMR*BlackLead115VAC input50/60 Hz.Used on PTC Models(example: ALTV2432600ULCB)XFMR*GroundConnected to Doornon-power limited non-power

Page 7 - TOP ONLY

- 7 -000.81"01.1875"1.1875"3.25"3.25"0 1.1875" 3.25".75" 1.5" 6.25" 11"1.4"6.5"5.5&qu

Page 8

- 8 -Altronix Corp.140 58th Street, Brooklyn, New York 11220 USA, 718-567-8181, fax: 718-567-9056web site: www.altronix.com, e-mail: [email protected]

Comments to this Manuals