Altronix AL600UL3 Installation Instructions User Manual

Browse online or download User Manual for Accessories for electrical Altronix AL600UL3 Installation Instructions. Altronix AL600UL3 Installation Instructions User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Rev. 120612
AL600UL3
AL600UL3X
Triple Output
Power Supply/Charger
Installation Guide
Altronix Corp.
140 58th St. Brooklyn, NY
For a red enclosure, add an “R” suffix to the part # e.g. AL600UL3R
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - AL600UL3X

Rev. 120612AL600UL3AL600UL3XTriple OutputPower Supply/ChargerInstallation GuideAltronix Corp.140 58th St. Brooklyn, NYFor a red enclosure, add an “R”

Page 2 - - 2 - AL600UL3/AL600UL3X

- 2 - AL600UL3/AL600UL3XOverview:The AL600UL3/AL600UL3X Triple Output Power Supply/Charger is specifically designed for use with access control an

Page 3 - Enclosure

AL600UL3/AL600UL3X - 3 - 4. Connect 5VDC devices to be powered at 5VDC to the terminals marked [+ 5VDC -- ].5. Connect 12VDC devices to be powered

Page 4 - Terminal Identification:

- 4 - AL600UL3/AL600UL3XMaintenance:Unitshouldbetestedatleastonceayearfortheproperoperationasfollows:OutputVoltageTest:Undernorm

Page 5 - A.2 Relays

AL600UL3/AL600UL3X - 5 - Appendix A - UL Listed Compatible DevicesA.1 Four (4) Wire Smoke DetectorsTable A-1 below lists four (4) wire smoke detect

Page 6 - - 6 - AL600UL3/AL600UL3X

- 6 - AL600UL3/AL600UL3XNotes:

Page 7 - Enclosure Dimensions (BC300):

AL600UL3/AL600UL3X - 7 - Enclosure Dimensions (BC300):AL600UL313.5”(342.9mm)x13”(330.2mm)x3.25”(82.55mm)1.40”(36mm)1.40”(36mm)4.85”(123mm)4.

Page 8 - Enclosure Dimensions (BC400):

- 8 - AL600UL3/AL600UL3XMEMBERAltronixisnotresponsibleforanytypographicalerrors.14058thStreet,Brooklyn,NewYork11220USA,718-567-818